Abstract
Power systems are subjected to a wide range of disturbances during daily operations. Severe disturbances, such as a loss of a large generator, a three-phase bolted fault on a generator bus, or a loss of a transmission line, can lead to the loss of synchronism of a generator or group of generators. The ability of a power system to maintain synchronism during the few seconds after being subjected to a severe disturbance is known as transient stability. Most of the modern methods of controlling transient stability involve special protection schemes or remedial action schemes. These special protection schemes sense predetermined system conditions and take corrective actions, such as generator tripping or generation re-dispatch, in real time to maintain transient stability. Another method is the use of a real-time feedback control system to modulate the output of an actuator in response to a signal. This paper provides a fundamental evaluation of the use of feedback control strategies to improve transient stability in a power system. An optimal feedback control strategy that modulates the real power injected and absorbed by distributed energy-storage devices is proposed. Its performance is evaluated on a four-machine power system and on a 34-machine reduced-order model of the Western North American Power System. The result shows that the feedback control strategy can increase the critical fault clearing time by 60%, thereby improving the transient stability of the power system.
AI Summary
This paper provides a broader evaluation of feedback-based transient-stability control using distributed energy-storage devices. It derives the controller from both the equal-area/energy-function perspective and a minimum-time optimal-control formulation, showing that both lead to a fast real-power modulation strategy based on generator frequency relative to the center-of-inertia frequency. The approach is tested on a four-machine system and a 34-machine reduced-order model of the Western North American Power System under severe disturbances. The simulations show substantial improvement in transient stability, with critical clearing time increasing as storage power rating increases and reaching an improvement of about 60% in the reported Western-system study. The paper also discusses implementation limits and future requirements, including storage capability, placement, communication, and practical deployment of wide-area feedback control.
Full Paper
The full paper is available from the publisher or an authoritative repository.
View Published Version ↗